Service poles 50 in LMP colour aluminium

Technical specification

Service poles 50 in LMP colour aluminium

Logo Unex

Description

Use

  • For supply of workstations from the ceiling in open-plan rooms
  • Easy maintenance and adaptable to future changes in the structure and location of the workstations.
  • Solid aluminium structure and rigid fixing system.
  • Pole’s socket boxes can accomodate all types of switches and sockets and they can be enlarged according to the requirements.
  • Fittings in two pieces which offers the possibility to mount the most common switches and sockets of the market assuring a solid fixing.

Design

  • Aluminium material in anodized aluminium grey colour.
  • Slender structures providing the minimum necessary diameter for wiring, easily adaptable to the space distribution and to any relocation.
  • Minimalist and modern design.

Installation

  • The pole's inner bar and the covers are cut at the required length. Ceiling fixing by pressure, with a non-skid joint.
  • The embellishing pieces allows the mounting from ceiling or suspended ceiling.
  • Pole’s socket boxes can be pre-wired in workshop before assembling on the site.
  • Cable retainers facilitates wiring and mounting of covers.
  • Covers and embellishing pieces fixing by pressure.
  • Covers with protective film. Ensures that the product remains in perfect conditions during transport and application.

Mounting instructions

  • To fulfil the characteristics defined herein, the installation must be carried out in accordance with the manufacturer`s assembly instructions provided in the main product packaging and are also available on the website www.unex.net.

Characteristics

Raw material
Service pole
Aluminium (See technical data for raw material).
Service pole socket box
U24X (See technical data for raw material).
Applications
Applications
Indoor installations.
Silicone contents
Silicone free
<0,01%
Directive 2011/65/EU
RoHS II Compliant
Compliant.
EN 50085-2-4:2009
Minimum storage and transport temperature
-45ºC
Minimum installation and application temperature
-5ºC
Maximum application temperature
+60ºC
Resistance against mechanical impacts during mounting and use
2 J at -5ºC
Resistance to flame propagation
Non-flame propagation.
Electrical continuity characteristic
With electrical continuity characteristic.
Electrical insulating characteristic
Without electrical insulating characteristic.
Protection degree assured by the enclosure
IP4X.
Retention of the system access cover
Cover removable only with the aid of a tool.
Electrically protective separation
With internal protective separation.
According to floor treatment
Service poles for wet-treatment of floor
According to resistance to vertical load applied through a small surface area
Not declared.
According to resistance to vertical load applied through a large surface area
Not declared.
Contraints concerning the number or configuration of assembled modules
No.
Whether non vertical mounting is allowed
No.
Whether the flexible component is not part of the enclosure
No.
Protection against mechanical damage
IK07
Rated Voltage
750 V
Linear impedance
2,82 10-8 Ohm/m
Fixing for apparatus mounting of socket outlets
Resistance to extraction of 81 N
EN 60695-2-11:2001
Glow-wire test
Severity degree: 960ºC.

Characteristics

Raw material

Service pole:
Aluminium (See technical data for raw material).
Service pole socket box:
U24X (See technical data for raw material).

Applications

Applications:
Indoor installations.

Silicone contents

Silicone free:
<0,01%

Directive 2011/65/EU

RoHS II Compliant:
Compliant.

EN 50085-2-4:2009

Minimum storage and transport temperature:
-45ºC
Minimum installation and application temperature:
-5ºC
Maximum application temperature:
+60ºC
Resistance against mechanical impacts during mounting and use:
2 J at -5ºC
Resistance to flame propagation:
Non-flame propagation.
Electrical continuity characteristic:
With electrical continuity characteristic.
Electrical insulating characteristic:
Without electrical insulating characteristic.
Protection degree assured by the enclosure:
IP4X.
Retention of the system access cover:
Cover removable only with the aid of a tool.
Electrically protective separation:
With internal protective separation.
According to floor treatment:
Service poles for wet-treatment of floor
According to resistance to vertical load applied through a small surface area:
Not declared.
According to resistance to vertical load applied through a large surface area:
Not declared.
Contraints concerning the number or configuration of assembled modules:
No.
Whether non vertical mounting is allowed:
No.
Whether the flexible component is not part of the enclosure:
No.
Protection against mechanical damage:
IK07
Rated Voltage:
750 V
Linear impedance:
2,82 10-8 Ohm/m
Fixing for apparatus mounting of socket outlets:
Resistance to extraction of 81 N

EN 60695-2-11:2001

Glow-wire test:
Severity degree: 960ºC.

Compulsory regulations

European Directive 2014/35/EU
CE Marking
Conformity with standard EN 50085-2-4:2009.

Compulsory regulations

European Directive 2014/35/EU

CE Marking:
Conformity with standard EN 50085-2-4:2009.

Characteristics of aluminium raw material

  • Base raw material: Aluminium
  • UL flammability tests on plastic materials according to ANSI/UL 94: 1990: Non-combustible (2)
  • Coefficient of linear expansion: 0,02 mm/ºCm (2)

Characteristics of U24X raw material

  • Base raw material: PVC.
  • Silicone contents: <0,01%. (3)
  • Phthalate contents according to ASTM D2124-99:2004: <0,01%. (3)
  • Dielectric strength: Insulating.
  • Reaction to fire s/UNE 201010:2015: Classification: M1
  • UL flammability tests on plastic materials according to ANSI/UL 94: 1990: Degree UL94: V0.
  • Resistance to ozone according to ASTM D-1149: No cracks magnified to 2.

Notes

1. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net

2. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.

3. Detection limit for the analytical technique applied.