File number E 75725 (M)
File number LR 86975
Trunkings. Type approval certificate nº 05116/I0/BV
Type approval certificate TAE00003J8
EN 50085-2-1:2006 + A1:2011
|
|
---|---|
Minimum transport and storage temperature
|
-45ºC
|
Minimum installation and application temperature
|
-25ºC
|
Maximum application temperature
|
+60ºC
|
Resistance to flame propagation
|
Non-flame propagator
|
Electrical features
|
Without electrical continuity.
|
Electrical insulating
|
With electrical insulation.
|
Degree of protection provided by enclosure
|
IP30
|
Retention of the system access cover
|
Cover removable without the aid of a tool.
|
Electrically protective separation
|
Without divider.
|
Intended installation positions
|
Montaje superficial en la pared.
|
Prevention of contact with liquids
|
Not applicable
|
Type
|
Type 1
|
Rated voltage
|
750 V
|
Protection against mechanical damage
|
IK04
|
EN 60695-2-11:2001
|
|
---|---|
Glow-wire test
|
Severity degree: 960ºC.
|
European Directive 2014/35/EU
|
|
---|---|
CE marking
|
Conformity with standard EN 50085-2-1:2006 + EN 50085-2-1/A1:2011
|
Electrical Equipment (Safety) Regulations 2016
|
|
---|---|
UKCA Marking
|
Conformity with Standard EN 50085-2-1:2006 + EN 50085-2-1/A1:2011
|
1. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net
2. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.