Logo Unex
Furniture supply 51 in LMP

Technical specification

Furniture supply 51 in Logo

Logo Unex

Description

Description

  • System of units and flexible runways to supply work posts from the ceiling, ground or wall to the centre of the furniture unit.
  • Fully flexible solutions that do not interfere with user mobility and can be adapted to the space available for the workplace set-up.

Characteristics of the flexible runway

  • Adjustable flexible runway that caters for all needs.
  • Features attachments to ceiling and Unex Trunking 93 and Floor Boxes 52.
  • A semi-transparent open runway model that facilitates the routing of cables plus a semi-transparent or graphite closed runway model with encircling rings that conceal and protect the cables.
  • Light, mobile design which blends in with the surrounding space, naturally adapting to the aesthetics of the room's furniture and fittings.

Characteristics of the furniture box

  • Furniture boxes available in two finishes: Anthracite or Grey RAL 7035, offering the widest range of integration with any environment.
  • Two-piece mechanism adaptors that allow any modular mechanism available on the market to be easily installed, ensuring a solid, secure mounting.
  • The box is expandable, providing a solution to all user needs.
  • Sturdy furniture mounting. Withstands plug removal.

System advantages

  • Independent installation makes expansion and relocation easier without damaging or interfering with the furniture.
  • Adaptable to differing furniture thicknesses.
  • Furniture boxes can be pre-wired in the workshop before installation.
  • Electrical insulation and separation of weak and strong currents.
  • The flexible runway protects cables and connections from accidental pulls and inappropriate handling.

Mounting instructions

  • To fulfil the characteristics defined herein, the installation must be carried out in accordance with the manufacturer`s assembly instructions provided in the main product packaging and are also available on the website www.unex.net.

Characteristics

Raw material
Furniture boxes and runway fixings
U24X (See technical data for raw material).
Flexible runway
PC. (See technical data for raw material).
Flexible runway lid
Stainless steel.
Applications
Applications
Indoor installations.
Silicone contents
Silicone free
<0,01%
Directive 2011/65/EU
RoHS II Compliant
Compliant.
EN 62549:2012
Minimum application temperature
-5ºC
Maximum application temperature
+60ºC
Resistance to impact
2 J at -5ºC
Installation onfloor
System not intended to be installed onfloor
Electrical continuity characteristic
Without electrical continuity characteristic.
Protection degrees provided by the system according to IEC 60529:1989
  • With Flexible runway 51602 or 51606, without protection degree.
  • With Closed rings runway 51601 or 51603, IP2X.
Minimum bending radius
  • 51601, 51603: 95 mm
  • 51602, 51606: 30 mm
Largest outer diameter of the cables to be mounted that can be used within the system
13 mm
Smallest outer diameter of the cables to be mounted that can be used within the system
9 mm
Usable cross-sectional
  • 51601, 51603: 525 mm2
  • 51602, 51606: 670 mm2
Glow-wire test
  • Flexible runway, flexible runway lid and flexible runway end cap. Severity degree: 750ºC.
  • Furniture boxes and trunking adapters. Severity degree: 960ºC
Protection against mechanical impact
IK07. Closed rings runways, 51601, 51603. Furniture boxes and adapters for trunkings supplied with the flexible runway.
Protection against solid particles, applicable to sockets according to IEC 60670-1.
IP4X. Furniture boxes and adapters for trunkings supplied with the flexible runway.
Fixing for apparatus mounting of socket outlets
Resistance to extraction of 81 N

Characteristics

Raw material

Furniture boxes and runway fixings:
U24X (See technical data for raw material).
Flexible runway:
PC. (See technical data for raw material).
Flexible runway lid:
Stainless steel.

Applications

Applications:
Indoor installations.

Silicone contents

Silicone free:
<0,01%

Directive 2011/65/EU

RoHS II Compliant:
Compliant.

EN 62549:2012

Minimum application temperature:
-5ºC
Maximum application temperature:
+60ºC
Resistance to impact:
2 J at -5ºC
Installation onfloor:
System not intended to be installed onfloor
Electrical continuity characteristic:
Without electrical continuity characteristic.
Protection degrees provided by the system according to IEC 60529:1989:
  • With Flexible runway 51602 or 51606, without protection degree.
  • With Closed rings runway 51601 or 51603, IP2X.
Minimum bending radius:
  • 51601, 51603: 95 mm
  • 51602, 51606: 30 mm
Largest outer diameter of the cables to be mounted that can be used within the system:
13 mm
Smallest outer diameter of the cables to be mounted that can be used within the system:
9 mm
Usable cross-sectional:
  • 51601, 51603: 525 mm2
  • 51602, 51606: 670 mm2
Glow-wire test:
  • Flexible runway, flexible runway lid and flexible runway end cap. Severity degree: 750ºC.
  • Furniture boxes and trunking adapters. Severity degree: 960ºC
Protection against mechanical impact:
IK07. Closed rings runways, 51601, 51603. Furniture boxes and adapters for trunkings supplied with the flexible runway.
Protection against solid particles, applicable to sockets according to IEC 60670-1.:
IP4X. Furniture boxes and adapters for trunkings supplied with the flexible runway.
Fixing for apparatus mounting of socket outlets:
Resistance to extraction of 81 N

Compulsory regulations

European Directive 2014/35/EU
CE Marking
Conformity with standard EN 62549:2012.

Compulsory regulations

European Directive 2014/35/EU

CE Marking:
Conformity with standard EN 62549:2012.

Characteristics of U24X raw material

  • Base raw material: PVC.
  • Silicone contents: <0,01%. (2)
  • Phthalate contents according to ASTM D2124-99:2004: <0,01%. (2)
  • Dielectric strength: Insulating.
  • Reaction to fire s/UNE 201010:2015: Classification: M1
  • UL flammability tests on plastic materials according to ANSI/UL 94: 1990: Degree UL94: V0.
  • Behaviour to chemicals exposure: DIN 8061 and ISO/TR 10358 standards indicate the performance of rigid PVC in front of a series of chemical products depending on its concentration and temperature.
    Resistant to the most common:
    - Oils (mineral, vegetable and paraffin emulsions)
    - Acids (diluted or concentrated)
    - Fat acids
    - Alcohols
    - Aliphatic carbon hydrides
    - Hydroxide
    - Saline solutions (3)
  • Resistance to ozone according to ASTM D-1149: No cracks magnified to 2.

Characteristics of polycarbonate raw material

  • Base Raw material: Polycarbonate
  • UL flammability tests on plastic materials according to ANSI/UL 94: 1990: degree UL94 V2 (3)
  • Behaviour to chemicals exposure: Resistant to the most common:
    - Oils
    - Acids
    - Alcohols
    - Fats
    - Carbon hydrides
    - Saline solutions (neutral or acids) (3)

Notes

1. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net

2. Detection limit for the analytical technique applied.

3. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.

04/11/2024