GOST R 52868:2007
POCC.RU.C-ES-AK01.H.02882/19
Type approval Certificate nº 05116/H0 BV
FZ-123-FZ
BS EN 61537:2007 (IEC 61537:2006) International Cable tray and Cable Ladder standard
|
|
---|---|
Min./max. Service, transport, storage, installation and use temperature
|
-20º C up to +90º C.
|
Protection against mechanical damage
|
20 J at -20ºC (except 60x100: 10 J).
|
Electrical characteristics
|
|
Resistance to flame propagation s/ EN 60695-11-2:2003(4)
|
Non flame propagating system.
|
Coating
|
60x200 mm. : 22,5 Kg/m
|
% perforation in the base area
|
|
Safe Working Load (SWL) acc. Test Type I
|
|
Safe Working Load (SWL) Test conditions
|
|
Glow-wire test acc./ IEC 60695-2-11:2001(4)
|
Severity degree 960ºC.
|
Resistance against humid and saline corrosion
|
Inherently resistant to corrosion. Test is not necessary.
|
EN 50085-2-1:2006 + A1:2011 Cable trunking european standard
|
|
---|---|
Material
|
Non metallic.
|
Minimum storage and transport temperature
|
-45ºC
|
Minimum installation and application temperature
|
-25ºC
|
Maximum application temperature
|
+60ºC
|
Resistance against mechanical impacts during mounting and use
|
Cable tray with cover: 20 J at -25ºC
|
Resistance to flame propagation acc./ IEC 60695-11-2:2003(5)
|
Non-flame propagation.
|
Electrical continuity characteristic
|
Without electrical continuity characteristic.
|
Electrical insulating characteristic
|
With electrical insulating characteristic.
|
Protection degree assured by the enclosure acc./ IEC 60529:1989(5)
|
|
Retention of the system access cover
|
Cover removable only with the aid of a tool.
|
Electrically protective separation
|
With and without internal protective separation.
|
Intended installation positions
|
Surface mounted on the wall.
|
Prevention of contact with liquids
|
Not declared.
|
Assured functions
|
Type 1. (Cable tray profile with cover, separator, cover fixing IK10 and end cover)
|
Rated Voltage(6)
|
750 V.
|
Protection against mechanical damage acc./ IEC 62262:2002(7, 5)
|
Cable tray with cover: Degree IK10.
|
Conformity with the demands of European Directive 2014/35/EU
|
|
---|---|
CE Marking(8)
|
Conformity with standard EN 61537:2007.
|
1. For aggressive chemical environments (concentrated acids ans hydroxides) we strongly recommend, if possible, the use of the product in U23X.
2. In outdoor installations or in aggressive chemical environments it is necessary to periodically check the installation. In outdoor installations, a colour change may occur on the raw material, without affecting its mechanical features. If painted, dark colored paints might cause further warming of the product once exposed to the sun.
3. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net
4. Tested according to standard prescriptions of EN 61537:2007 . Equivalent to IEC 61537:2006 Cable tray and cable ladder standard.
5. Tested according to standard prescriptions of EN 50085-1
6. Test carried out considering the use of the cable tray with cover to provide additional insulation to an isolated conductor according to requirements of EN 50085-1 standard (Low Voltage Directive)
7. Mounted with Cover fixing Ref. 66845-44 or 66855-44. Without this device: Impact resistance 2J and Protection against mechanical damages Grade IK07.
8. The values indicated according to IEC 61537:2006 have been tested under its European implementation EN 61537:2007.
9. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.