Logo Unex
Cable ties 22 in LMP

Technical specification

Cable ties 22 in Logo

Logo Unex

Description

  • For tying of cables and conduits for indoor use.(1)
  • Hand thread, easier mounting at site.
  • High tensile strength.
  • UL approval for finished product.
  • Inside teeth.
  • Own raw material. Insulating halogen free material.
  • RoHS II Compliant.
  • Colour: Natural.

Quality Marks(2)

EN IEC 62275:2019
Licence nº: 030/001929

EN 62275:2015
Licence nº: NF004_1127

EN IEC 62275:2019
Licence nº:40011920

(3)

UL 62275:2016
File E 75725 (M)

UL 62275:2016
File E 75725 (M)

Approvals(2)

Certificat d´Approbation de type nº 04934/I0/BV

(4)

Según NI 5.70.12.01 Abrazaderas para cables aislados y aplicaciones varias

Characteristics

EN IEC 62275:2019
Component
Non metallic.
Minimum installation temperature
-30ºC
Service temperature
-40ºC to +85ºC
Contribution to fire
Non-flame propagation.
Resistance to UVs
Not Declared.
Resistance to traction (minimum tensile strength)
  • 8,16 Kg for cable ties of 2,5 mm
  • 13,6 Kg for cable ties of 3,6 mm
  • 22,6 Kg for cable ties of 4,8 mm
  • 54,4 Kg for cable ties of 7,6 mm
  • Type 1: cable ties of 2,5 mm and 3,6mm .
  • Type 2: cable ties of 4,8 mm and 7,6mm.
Max./Min. application diameter
  • 2221: 22mm / 1,6mm
  • 2225: 50mm / 1,6mm
  • 2233: 32mm / 1,6mm
  • 2235: 50mm / 1,6mm
  • 2237: 76mm / 1,6mm
  • 2244: 45mm / 1,6mm
  • 2247: 76mm/ 1,6mm
  • 2249: 102mm / 1,6mm
  • 2271: 50mm / 4,8mm
  • 2272: 76mm / 4,8mm
  • 2273: 102mm /4,8mm
  • 2275: 150mm /4,8mm
  • 2278: 203mm / 4,8mm
MS 3367
Dimensions(5)
  • 2221: MS 3367-4
  • 2225:-
  • 2233: MS 3367-5
  • 2235: -
  • 2237: -
  • 2244: MS 3367-1
  • 2247: MS 3367-7
  • 2249: MS 3367-2
  • 2271: -
  • 2272: -
  • 2273: MS 3367-3
  • 2275: -
  • 2278: MS 3367-6

Characteristics

EN IEC 62275:2019

Component:
Non metallic.
Minimum installation temperature:
-30ºC
Service temperature:
-40ºC to +85ºC
Contribution to fire:
Non-flame propagation.
Resistance to UVs:
Not Declared.
Resistance to traction (minimum tensile strength):
  • 8,16 Kg for cable ties of 2,5 mm
  • 13,6 Kg for cable ties of 3,6 mm
  • 22,6 Kg for cable ties of 4,8 mm
  • 54,4 Kg for cable ties of 7,6 mm
  • Type 1: cable ties of 2,5 mm and 3,6mm .
  • Type 2: cable ties of 4,8 mm and 7,6mm.
Max./Min. application diameter:
  • 2221: 22mm / 1,6mm
  • 2225: 50mm / 1,6mm
  • 2233: 32mm / 1,6mm
  • 2235: 50mm / 1,6mm
  • 2237: 76mm / 1,6mm
  • 2244: 45mm / 1,6mm
  • 2247: 76mm/ 1,6mm
  • 2249: 102mm / 1,6mm
  • 2271: 50mm / 4,8mm
  • 2272: 76mm / 4,8mm
  • 2273: 102mm /4,8mm
  • 2275: 150mm /4,8mm
  • 2278: 203mm / 4,8mm

MS 3367

Dimensions:(5)
  • 2221: MS 3367-4
  • 2225:-
  • 2233: MS 3367-5
  • 2235: -
  • 2237: -
  • 2244: MS 3367-1
  • 2247: MS 3367-7
  • 2249: MS 3367-2
  • 2271: -
  • 2272: -
  • 2273: MS 3367-3
  • 2275: -
  • 2278: MS 3367-6

Compulsory regulations

2014/35/EU European Directive
CE Marking
Conformity with standard EN IEC 62275:2019.
Electrical Equipment (Safety) Regulations 2016
UKCA Marking
Conformity with Standard EN IEC 62275:2019.

Compulsory regulations

2014/35/EU European Directive

CE Marking:
Conformity with standard EN IEC 62275:2019.

Electrical Equipment (Safety) Regulations 2016

UKCA Marking:
Conformity with Standard EN IEC 62275:2019.

Characteristics of U60X raw material

  • Base raw material: Polyamide 6.6 (natural colour and grey RAL 7035 colour)
  • Halogen contents according to EN 50642: 2018: Halogen free
  • Silicone contents: silicone free
  • Phthalate contents according to ASTM D2124-99:2004: phthalate free
  • UL flammability tests on plastic materials according to ANSI/UL 94: 1990: Degree UL94 V2
  • L.O.I. Oxygen index according to EN ISO 4589:1999: >=29
  • Behaviour to chemicals exposure: Resistant to the most common:
    - Hydroxides
    - Oils
    - Fats
    - Carbon hydrides
    - Acetone
    - Chlorated solvents
    The zinc of the galvanized affects the life utility of polyamide 6.6 in front of agressive agents (chemical agent and UVs). (6)
  • UL Approval: File E41938 EM
  • Classification acc./ASTM D6779:2003: PA 0111

Notes

1. Due to the variety of factors affecting the performance of the cable ties under chemical agents (concentration, temperature, Uvs, mounting way, etc),the particular atmosphere of certain installations must be individually studied with a specific test.

2. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net

3. Cable ties width 4,8 and 7,6 mm

4. Certified references: 2221; 2225; 2233; 2235; 2237; 2244; 2247; 2249; 2271; 2272; 2273; 2278.

5. Cable ties without MS designation fulfill the conditions set in the standards for items with the same width, except for the length.

6. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.

03/10/2024