Description

  • For tying of cables and conduits in outdoor and indoor installations.(1)
  • Complete product family for all kind of applications.
  • Hand thread, easier mounting at site.
  • High tensile strength.
  • Resistance to UVs according to the standard EN 62275:2019.
  • UL approval both for raw material and finished product.
  • Inside teeth.
  • Own raw material. Insulating halogen free material.
  • RoHS II Compliant
  • Colour: black.

Quality Marks(2)

(3)

EN IEC 62275:2019
Licence nº: 030/001929

EN 62275:2015
Licence nº: NF004_1127

EN IEC 62275:2019
Licence nº: 40011920

(4)

UL 62275:2016
File E 75725 (M) Up to 85ºC

UL 62275:2016
File E 75725 (M) Up to 85ºC

Approvals(2)

Certificat d´Approbation de type nº 04934/I0/BV

Type approval certificate TAE0000115

(5)

According to NIDSA 5.70.12.01

Characteristics

EN IEC 62275:2019
Component
Non metallic.
Minimum installation temperature
-30ºC
Service temperature
-40ºC to +105ºC
Contribution to fire
Non-flame propagation.
Resistance to UVs
Resistant.
Resistance to traction (minimum tensile strength)
  • 8,16 Kg for cable ties of 2,5 mm
  • 13,6 Kg for cable ties of 3,6 mm
  • 22,6 Kg for cable ties of 4,8 mm
  • 54,4 Kg for cable ties of 7,6 mm
  • 117,3 Kg for cable ties of 12,7 mm
  • Type 1: cable ties of 2,5 mm, 3,6mm and 12,7mm.
  • Type 2: cable ties of 4,8 mm and 7,6mm.
Max./Min. application diameter
  • 2221-0: 22 mm / 1,6 mm
  • 2225-0: 50 mm / 1,6 mm
  • 2233-0: 32 mm / 1,6 mm
  • 2235-0: 50 mm / 1,6 mm
  • 2237-0: 76 mm / 1,6 mm
  • 2244-0: 45 mm / 1,6 mm
  • 2247-0: 76 mm/ 1,6 mm
  • 2249-0: 102 mm / 1,6 mm
  • 2250-0: 150 mm / 1,6 mm
  • 2271-0: 50 mm / 4,8 mm
  • 2272-0: 76 mm / 4,8 mm
  • 2273-0: 102 mm / 4,8 mm
  • 2275-0: 150 mm / 4,8 mm
  • 2278-0: 203 mm / 4,8 mm
  • 2296-0: 298 mm / 70 mm
  • 2298-0: 362 mm / 70 mm
MS 3367
Dimensions(6)
  • 2221-0: MS 3367-4
  • 2225-0: -
  • 2233-0: MS 3367-5
  • 2235-0: -
  • 2237-0: -
  • 2244-0: MS 3367-1
  • 2247-0: MS 3367-7
  • 2249-0: MS 3367-2
  • 2250-0: -
  • 2271-0: -
  • 2272-0: -
  • 2273-0: MS 3367-3
  • 2275-0: -
  • 2278-0: MS 3367-6
  • 2296-0: -
  • 2298-0: -

Characteristics

EN IEC 62275:2019

Component:
Non metallic.
Minimum installation temperature:
-30ºC
Service temperature:
-40ºC to +105ºC
Contribution to fire:
Non-flame propagation.
Resistance to UVs:
Resistant.
Resistance to traction (minimum tensile strength):
  • 8,16 Kg for cable ties of 2,5 mm
  • 13,6 Kg for cable ties of 3,6 mm
  • 22,6 Kg for cable ties of 4,8 mm
  • 54,4 Kg for cable ties of 7,6 mm
  • 117,3 Kg for cable ties of 12,7 mm
  • Type 1: cable ties of 2,5 mm, 3,6mm and 12,7mm.
  • Type 2: cable ties of 4,8 mm and 7,6mm.
Max./Min. application diameter:
  • 2221-0: 22 mm / 1,6 mm
  • 2225-0: 50 mm / 1,6 mm
  • 2233-0: 32 mm / 1,6 mm
  • 2235-0: 50 mm / 1,6 mm
  • 2237-0: 76 mm / 1,6 mm
  • 2244-0: 45 mm / 1,6 mm
  • 2247-0: 76 mm/ 1,6 mm
  • 2249-0: 102 mm / 1,6 mm
  • 2250-0: 150 mm / 1,6 mm
  • 2271-0: 50 mm / 4,8 mm
  • 2272-0: 76 mm / 4,8 mm
  • 2273-0: 102 mm / 4,8 mm
  • 2275-0: 150 mm / 4,8 mm
  • 2278-0: 203 mm / 4,8 mm
  • 2296-0: 298 mm / 70 mm
  • 2298-0: 362 mm / 70 mm

MS 3367

Dimensions:(6)
  • 2221-0: MS 3367-4
  • 2225-0: -
  • 2233-0: MS 3367-5
  • 2235-0: -
  • 2237-0: -
  • 2244-0: MS 3367-1
  • 2247-0: MS 3367-7
  • 2249-0: MS 3367-2
  • 2250-0: -
  • 2271-0: -
  • 2272-0: -
  • 2273-0: MS 3367-3
  • 2275-0: -
  • 2278-0: MS 3367-6
  • 2296-0: -
  • 2298-0: -

Compulsory regulations

2014/35/EU European Directive
CE Marking
Conformity with standard EN IEC 62275:2019.
Electrical Equipment (Safety) Regulations 2016
UKCA Marking
Conformity with Standard EN IEC 62275:2019.

Compulsory regulations

2014/35/EU European Directive

CE Marking:
Conformity with standard EN IEC 62275:2019.

Electrical Equipment (Safety) Regulations 2016

UKCA Marking:
Conformity with Standard EN IEC 62275:2019.

Characteristics of U61X (black colour) raw material

  • Base raw material: Polyamide 6.6 weather-stabilized (black colour)
  • Halogen contents according to EN 50642: 2018: Halogen free
  • Silicone contents: 0,025%
  • Phthalate contents according to ASTM D2124-99:2004: <0,01% (7)
  • UL flammability tests on plastic material according to ANSI/UL 94: 1990: degree UL94 V2
  • Behaviour to chemicals exposure: Resistant to the most common:
    - Hydroxides
    - Oils
    - Fats
    - Carbon hydrides
    - Acetone
    - Chlorated solvents
    The zinc of the galvanized affects the life utility of polyamide 6.6 in front of agressive agents (chemical agent and UVs). (8)
  • Outdoor performance: Weatherized.
    Suitable for outdoor use according to ASTM D 6779-07
  • Bacteria and fungus: Good resistance to bacteria, fungus and insects attack. (8)
  • UL Approval: UL File E7317944
  • Classifications according to ASTM D6779:2003: PA 0192

Notes

1. Due to the variety of factors affecting the performance of the cable ties under chemical agents (concentration, temperature, Uvs, mounting way, etc),the particular atmosphere of certain installations must be individually studied with a specific test.

2. Except for new part numbers, which are under process of obtaining quality marks and approvals. See updated information of each part number on www.unex.net

3. 2296-0 and 2298-0 Licence nº: 030/001929

4. Cable ties width 4,8 and 7,6 mm

5. Certified part numbers: 2221-0; 2225-0; 2233-0; 2235-0; 2237-0; 2244-0; 2247-0; 2247-0; 2249-0; 2271-0; 2272-0; 2273-0; 2278-0.

6. Cable ties without MS designation fulfill the conditions set in the standards for items with the same width, except for the length.

7. Detection limit for the analytical technique applied.

8. All features marked are based on random tests of the material in the manufacture of our products. However, they only reflect the values accepted by the raw material manufacturers, which are provided only as information and guidance.

03/10/2024